SKRIPSI

Penulis / NIM
ANDRIS KATILI / 521409003
Program Studi
S1 - TEKNIK ELEKTRO
Pembimbing 1 / NIDN
LANTO MOHAMAD KAMIL AMALI, MT / 0004047704
Pembimbing 2 / NIDN
ADE IRAWATY TOLAGO, ST, MT / 0914027501
Abstrak
KARAKTERISTIK TEGANGAN FLASHOVER DAN ARUS BOCOR PADA ISOLATOR 20 KV YANG TERKONTAMINASI POLUTAN GARAM LAUT Andris Katili 521409003 Intisari Jaringan distribusi primer 20 kV di indonesia merupakan saluran udara tegangan menengah (SUTM), yang dalam penyaluran energi listrik pada pelanggan memerlukan tiang listrik dan isolator yang memisahkan konduktor dengan tiang listrik. Isolator ini berhubungan langsung dengan udara luar sehingga dalam penyalurannya dipengaruhi oleh lingkungan alam. Dalam penelitian ini, 3 buah tipe isolator keramik 20 kV diuji karakteristik tegangan flashover dan arus bocor pada kondisi bersih kering, bersih basah, kering terkontaminasi dan basah terkontaminasi yang diatur kondisi polutannya. Polutan yang akan digunakan sebagai kontaminasi pada isolator ini merupakan polutan garam yang dilakukan dengan cara buatan dengan komposisi unsur kimiawinya menyerupai iklim daerah pantai. Dari hasil pengujian nilai tegangan flashover dan arus bocor dari ke 3 isolator uji tipe pin, tipe post dan tipe pin post bervariasi. Hal ini disebabkan karena adanya kontaminasi polutan terhadap permukaan isolator uji, nilai tegangan flashover dan arus bocor rata-rata maksimum tertinggi pada kondisi terpolusi basah (dengan penyemprotan polutan garam dari air laut yang berada di pesisir pantai), diperoleh tegangan fleshofer terbesar pada isolator tipe pin sebesar 14,27 kV dan arus bocor terbesar pada isolator tipe pin post sebesar 0,316 mA. Hal ini menunjukkan bahwa polutan garam dari air laut yang berada di pesisir pantai memberikan pengaruh negatif yang cukup besar terhadap kinerja isolator. Kata Kunci : Isolator, Polutan, Flashover, Arus Bocor Abstract The primer network distribution 20 KV in Indonesia is a medium voltage air-duct (SUTM), which is the distribution of electricity to the customer needs electrical-post and isolator which separate conductor with the electrical-post itself. This isolator is directly connected with outer air and makes the distribution influenced by nature. In this researcher, 3 (three) types of isolator were tested by the characteristic of its flashover voltage and leak current when the condition is dry clean, wet clean, and dry contaminated and wet contaminated in which the pollution condition was set. The pollution will be used for contaminating the isolator is acid pollution made by some chemical process of climate in coast area. The result of the test of flashover voltage and leak current from the test of three isolators that are pin type, post type, and pin post, was varied. It is caused by the pollution contamination towards the surface of isolator test, the value of flashover voltage and leak current is in the high average in wet condition of pollution (with the syringe of acid pollution which located on the coastal area). It was found that the biggest flashover voltage in pin isolator is 14.27 KV and the leak current in pin post isolator is 0.316 mA. It indicates that the acid water pollution in coastal area gives a big negative influence towards the function of isolator. Keywords: Isolator, Pollution, Leak current.
Download berkas

ARSIP

2024
Skripsi tahun 2024
2023
Skripsi tahun 2023
2022
Skripsi tahun 2022
2021
Skripsi tahun 2021
2020
Skripsi tahun 2020
2019
Skripsi tahun 2019
2018
Skripsi tahun 2018
2017
Skripsi tahun 2017
2016
Skripsi tahun 2016
2015
Skripsi tahun 2015
2014
Skripsi tahun 2014
2013
Skripsi tahun 2013
2012
Skripsi tahun 2012
2011
Skripsi tahun 2011