SKRIPSI

Penulis / NIM
ISMAIL AHMAD / 521411013
Program Studi
S1 - TEKNIK ELEKTRO
Pembimbing 1 / NIDN
LANTO MOHAMAD KAMIL AMALI, MT / 0004047704
Pembimbing 2 / NIDN
ERVAN HASAN HARUN, M.T. / 0025117408
Abstrak
ABSTRAK Ismail Ahmad, 2018. Studi Breakdown Voltage Bahan Isolasi PVC Dan XLPE Kabel Instalasi Listrik. Skripsi, Program Studi S1 Teknik Elektro, Jurusan Teknik Elektro, Fakultas Teknik, Universitas Negeri Gorontalo. Pembimbing I Bapak L.M Kamil Amali, ST.,MT dan Pembimbing II Bapak Ervan Hasan Harun, ST.,MT. Kabel listrik merupakan kawat penghantar berisolasi sebagai media untuk menyalurkan energi listrik dari satu tempat. Kabel yang akan digunakan pada sistem instalasi listrik dalam rumah/gedung maupun dalam sistem jaringan distribusi/transmisi tenaga listrik harus memenuhi standar rating tegangan yang ditentukan baik dari segi bahan konduktor/penghantar, bahan isolasi dan seluruh konstruksi kabelnya. Masalah yang paling sering dihadapi pada kabel listrik ini adalah kegagalan isolasinya berupa breakdown voltage. Breakdown voltage pada kabel mempengaruhi kesinambungan serta kualitas penyaluran energi listrik. Pengujian breakdown voltage dilakukan pada kabel listrik yang berbahan isolasi PVC dan XLPE dengan tipe kabel yang diuji adalah NYM, NYA, NYAF, NYMHY, NYY serta kabel tegangan menengah yaitu : kabel NA2XSY. Hasil pengujian menunjukkan kabel yang berlabel standar yang diuji telah memenuhi persyaratan uji breakdown voltage berdasarkan standar PLN (SPLN) 04-6629.4 dan standar IEC 60502-2, sedangkan kabel non-standar tidak memenuhi persyaratan uji breakdown voltage. Kata kunci : breakdown voltage, isolasi kabel PVC dan XLPE, karakteristik ABSTARACT Ismail ahmad, 2018. A Study on Breakdown Voltage of PVC Insulation Material and XLPE Cable Insulation. Skripsi, Bachelor Sutdy Program of Electrical Enggineering, Department of Electrical Enggineering, Faculty of Enggineering, State University of Gorontalo. The principal supervisor is L.M Kamil Amali, ST.,MT and the co-supervisor is Ervan Hasan Harun, ST.,MT. A power cable is an insulated conductive wire used as a media to conduct electrical energy form a place. The wire which will be used in electrical installation system in a house/building or a distribution network system/electric power transmission has to meet voltage ratting standard that is determined either from conductor material, insulator and all the wire construction. The most often problem encountered in the power cable is isolation failure in the form of breakdown voltage. Breakdown voltage in the cable influences continuity and quality of electrical energy distribution. Breakdown voltage test is conducted in power cable made from PVC and XLPE with the cable types tested are NYM, NYA, NYAF, NYMHY, NYY and medium voltage cable: NA2XSY cable. The test result shows that standard cable which is tested has met the criteria of breakdown voltage based on the standard of State Electricity enterprice (SPLN) 04-6629.4 and IEC standard 60502-2, meanwhile non-standard cable does not meet the criteria of breakdown voltage test. Keywords : breakdown voltage, PVC and XLPE cable insulation, characteristic
Download berkas

ARSIP

2024
Skripsi tahun 2024
2023
Skripsi tahun 2023
2022
Skripsi tahun 2022
2021
Skripsi tahun 2021
2020
Skripsi tahun 2020
2019
Skripsi tahun 2019
2018
Skripsi tahun 2018
2017
Skripsi tahun 2017
2016
Skripsi tahun 2016
2015
Skripsi tahun 2015
2014
Skripsi tahun 2014
2013
Skripsi tahun 2013
2012
Skripsi tahun 2012
2011
Skripsi tahun 2011