SKRIPSI

Penulis / NIM
AGUNG ANWAR / 521411022
Program Studi
S1 - TEKNIK ELEKTRO
Pembimbing 1 / NIDN
LANTO MOHAMAD KAMIL AMALI, MT / 0004047704
Pembimbing 2 / NIDN
YASIN MOHAMAD, ST., MT. / 0022027105
Abstrak
ABSTRAK Agung Anwar, 2018. Pengaruh Polutan Taklarut Terhadap Kinerja Isolator. (studi kasus PLTU Molotabu), Skripsi, Program Studi S1 Teknik Elektro, Jurusan Teknik Elektro, Fakultas Teknik, Universitas Negeri Gorontalo. Pembimbing I Bapak L.M Kamil Amali, ST.,MT dan Pembimbing II Bapak Yasin Mohamad, ST.,MT. Penelitian ini bertujuan untuk memperoleh informai mengenai tegangan lewat denyar dan arus bocor yang diakibatkan oleh iklim serta polusi pembakaran batu bara yang menyebabkan adanya pelapisan polutan dipermukaan isolator. Metoda pemberian lapisan polutan pada permukaan isolator dengan cara menyemprotkan polutan pada permukaan isolator dengan beberapa kondisi pengujian. Metode pegujianya dengan cara diberikan tegangan tinggi sampai terjadi tegangan lewat denyar. Data hasil pengukuran memperlihatkan bahwa, terdapat hubungan yang signifikan antara polutan yang dilapisi pada permukaan isolator dan ESDD yang melekat pada permukaan isolator. Hasil penelitian dapat disimpulkan bahwa dari beberapa kondisi pengujian, maka pada kondisi kering takberpolutan nilai tegangan lewat denyar paling tinggi dan pada kondisi basah perpolutan nilai tegangan lewat denyar paling rendah. Kata kunci : tegangan lewat denyar, isolasi pinpost, polutan, NSDD ABSTRACT Agung Anwar, 2018. The Effect of Insoluble Pollutanst on Insulator Performance. (A Case Study at PLTU Molotabu), Skripsi, Bachelor of Electrical Engineering Study Program, Dapartment of Electrical Engineering, Faculty of Engineering, State University of Gorontalo. The principal supervisor is L.M Kamil Amali, ST, MT, and the co-supervisor is Yasin Mohamad, ST., MT. This research aims to acquire information about pulsating voltage and leakage current caused by the climate and coal burning pollution that brings about coating of a pollutant one the surface of the insulator. The method pf giving pollutant layer one the surface of the insulator was performed by spraying pollutant layer on the surface of the insulator with a few testing conditions. The testing method is by high voltage occurs. The measurement data shows that there is a significant relationship between pollutant coated on the surface of insulator and ESDD attached to insulator surface. It can be concluded that from some testing conditions; non-pollutant in a dry condition, the value of pulsating voltage is the lowest. Keywords: pulsating voltage, pin post insulator, pollutant, NSDD
Download berkas

ARSIP

2024
Skripsi tahun 2024
2023
Skripsi tahun 2023
2022
Skripsi tahun 2022
2021
Skripsi tahun 2021
2020
Skripsi tahun 2020
2019
Skripsi tahun 2019
2018
Skripsi tahun 2018
2017
Skripsi tahun 2017
2016
Skripsi tahun 2016
2015
Skripsi tahun 2015
2014
Skripsi tahun 2014
2013
Skripsi tahun 2013
2012
Skripsi tahun 2012
2011
Skripsi tahun 2011