ESSAY

Writer / NIM
WAHID / 521410038
Study Program
S1 - TEKNIK ELEKTRO
Advisor 1 / NIDN
YASIN MOHAMAD, ST., MT. / 0022027105
Advisor 2 / NIDN
ADE IRAWATY TOLAGO, ST, MT / 0914027501
Abstract
Intisari Kualitas tegangan adalah salah satu hal penting dalam sistem tenaga listrik, baik itu pada jaringan distribusi primer maupun pada jaringan distribusi sekunder. Menganalisis kualitas tegangan dilakukan guna mengetahui stabilitas tegangan pada beban yang terpasang. Dalam penelitian ini digunakan metode kurva P - V dan kurva Q - V untuk menganalisis kualitas tegangan yang ditinjau dari sisi pembebanan dengan didukung menggunakan perangkat lunak ETAP, kemudian dievaluasi kualitas tegangannya berdasarkan standar PLN (SPLN : 72 Tahun 1987) dan berdasarkan standar IEEE std 446 "Recommended Practice for Emergency and Standby Power System for Industrial and Commercial Applications" Dari hasil penelitian diperoleh, kualitas tegangan RSUD Prof. Dr. H. Aloei Saboe dalam kondisi sangat baik, tegangan pada kondisi beban bertambah 25 % dari beban puncak adalah 216,1 volt, drop tegangannya hanya 3,9 volt atau sebesar 1,77 % dari tegangan nominal, drop tegangan yang terjadi masih dalam batas yang diijinkan yaitu 13 % atau 191,4 volt. Kata Kunci : drop tegangan, kurva P-V, kurva Q-V, kualitas tegangan ABSTRACT The voltage quality is one of the important things in electric power systems in both the primary distribution network as well as on the secondary distribution network. Analyze the quality of voltage is done in order to find out the stability of the voltage on the load. This research used the curve method P - V and Q - V to analyze the quality of the voltage curve, which is viewed from the side burden supported using ETAP software then evaluated based on the standard of PLN (SPLN: 72 Year 1987) and based on standards IEE std 446 "recommended practice for emergency and standby power system for industrial and commercial applications" The results of this research obtained by the voltage quality in hospital Prof. Dr. H. Aloei Saboe in excellent condition. The voltage on the load was increased 25 % of peak loads is 216,1 volt, the voltage drop only 3,9 volt or 1,77 % of the nominal voltage, the voltage drop that occurs still within the allowable limit, theat is 13 % or 191,4 volt Key word: voltage drop, Curve P - V, Curve Q - V, Quality of voltage
Download files

ARCHIVES

2024
Year Essay 2024
2023
Year Essay 2023
2022
Year Essay 2022
2021
Year Essay 2021
2020
Year Essay 2020
2019
Year Essay 2019
2018
Year Essay 2018
2017
Year Essay 2017
2016
Year Essay 2016
2015
Year Essay 2015
2014
Year Essay 2014
2013
Year Essay 2013
2012
Year Essay 2012
2011
Year Essay 2011